Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • FLUKE
  • Thermometer FLUKE 1587 INSULATION MULTIMETER

Thermometer FLUKE 1587 INSULATION MULTIMETER

Update Terakhir
:
25 / 04 / 2020
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
13 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Thermometer FLUKE 1587 INSULATION MULTIMETER

FLUKE 1587 Insulation Multimeter Two powerful tools The Fluke 1587 Insulation Multimeters combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance. Whether you work on motors, generators, cables, or switch gear, the Fluke 1587 Insulation Multimeters are ideally suited to help you with your tasks and at a cost that is far less than buying the two products. SPECIFICATION : Specifications Voltage DC Maximum Voltage: 1000 V Accuracy: 1577: ± ( 0.2% + 2) 1587: ± ( 0.09% + 2) Maximum Resolution: 0.001V Voltage AC Maximum Voltage: 1000 V Accuracy: 1577: ± ( 2% + 3) 1587: ± ( 2% + 3) AC Bandwidth: 1587: 5kHz* * with low pass filter; 3db @ 800 Hz Maximum Resolution: 0.1 mV Current DC Maximum Amps: 400mA Amps Accuracy: 1577: ± ( 1.0% + 2) 1587: ± ( 0.2% + 2) Maximum Resolution: 0.01 mA Current AC Maximum Amps: 400mA Amps Accuracy: 1577: ± ( 2.0% + 2) * 1587: ± ( 1.5% + 2) * * 1kHz bandwidth Maximum Resolution: 0.01 mA Resistance Maximum Resistance: 50 M© Accuracy: 1577: ± ( 1.2% + 2) 1587: ± ( 0.9% + 2) Maximum Resolution: 0.1© Capacitance( 1587 only) Maximum Capacitance: 9, 999 µ F Accuracy: ± ( 1.2% + 2) Maximum Resolution: 1 nF Frequency ( 1587 only) Maximum Frequency: 100 kHz Accuracy: ± ( 0.1% + 1) Maximum Resolution: 0.01 Hz Temperature Measurement ( 1587 only) -40.0 ° C to 537 ° C -40.0 ° F to 998 ° F excluding probe Diode Test ( 1587 only) Range: 6 V Resolution: 1 mV Accuracy: ± ( 2 % + 1) Insulation Test Minimum Test Current @ 1k© / V: 1mA Test Voltages: 1577: 500, 1000 V 1587: 50, 100, 250, 500, 1000 V Maximum Resistance per Test Voltage: 50V: 100V: 250V: 500V: 1000V: 1577: 600 M© 1587: 2 G© Maximum Resolution per Test Voltage: 50V: 0.01 M© 100V: 0.01 M© 250V: 0.1 M© 500V: 0.1 M© 1000V: 0.1 M© Accuracy per Test Voltage: 50V: ± ( 3 % + 5) 100V: ± ( 3 % + 5) 250V: ± ( 1.5 % + 5) 500V: 1577: ± ( 2.0 % + 5) 1587: ± ( 1.5 % + 5) 1000V: 1577: ± ( 2.0 % + 5) 1587: ± ( 1.5 % + 5) to 600 M© , ± ( 10 % + 3) above 600 M© Environmental Specifications Operating temperature – 20 ° C to + 55 ° C Storage temperature -40° C to + 60° C Humidity ( Without Condensation) 0% - 95% ( 10 ° C – 30 ° C) 0% - 75% ( 30 ° C – 40 ° C) 0% - 40% ( 40 ° C – 55 ° C) Operating Altitude 2000 m Safety Specifications Overvoltage category Complies with ANSI/ ISA 82.02.01 ( 61010-1) 2004, CAN/ CSA-C22.2 NO. 61010-1-04, and IEC/ EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V Agency Approvals 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V Mechanical & General Specifications Size 203 x 100 x 50 mm ( with holster) Weight 624 g Warranty 1 years Battery life Alkaline Meter use: 1000 hours Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M© with a duty cycle of 5 seconds on and 25 seconds off. IP Rating IP40 Includes: Remote probe Test leads Alligator clips K-type thermocouple Hard case Four AA alkaline batteries Quick Reference Guide CD Rom with Manual




Info lebih lanjut silahkan hubungi kami:
HARAPAN ANAK JAYA
ptharapananakjaya@gmail.com
02135969127
081381483316
085775845308
Tampilkan Lebih Banyak